1. Product name: K2549 1"  RCAC25T3 RCAC25FS3 RCAC25DD3 Pulse Valve Goyen Diaphragm Repair Kit


2. Description:

Superior performance, easy maintenance diaphragm valve available with threaded ports (T3), dresser nut ports (DD3) or flange and slide ports (FS3). Outlet at 90° to inlet. 3 Series valves are available as remote pilot valves and may be converted to integral pilot applications through the use of the screw in pilots of the MIP and 3DS series.  


3. Suitable for

Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.


4. Operation

Recommended  on time range: 50-500ms 

Recommended time  between pulses: 1 minute or greater


5. Installation

For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure. 

1.Prepare supply and blowtube pipes* to suit valve type and specification. Avoid installing valves underneath the tank. 

2. Ensure tank and pipes are free from dirt, rust or other particulate.  

3. Ensure supply air is clean and dry.  

4. Mount valves to inlet pipes (or flanges, tighten bolts to 10Nm) and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. Ensure blowtube is fully inserted into the valve outlet. 

5. Tanks and pipes must be independently restrained from FS and DD valves.  

6. Connect RCAC pilot port to remote pilot valve, or install MIP/3DS screw in  pilot valve.  

7. Apply moderate pressure to system and check for installation leaks.  

8. Fully pressurise system.  

9. Test fire and listen for proper actuation and crisp pulse noise.


6.Drawing

Drawing


7.Product show

IMG_1258



Previous: 
Next: 

CONTACT US

  Company:Ningbo Fly Automation Co., Limited
 Contacts:Airwolf
  Phone:+0086-18957877638
 Tel:0086-574-88871448
  Fax:0086-574-56655151  
 QQ/Wechat:625118373
 Skype:flypmc@hotmail.com 
 E-mail:airwolf@fly-pneumatic.com
 
Copyright  2015 Ningbo Fly Automation Co., Limited. All rights reserved.  Supported by 宁波谷谷米网络科技有限公司